Routine optical and also mechanical maintenance of compound microscopes have the right to ensure that your microscope works well because that years. The microscopic lense maintenance information provided below is not expected to change any particular directions had with your microscope and also periodic microscope servicing by a qualified microscope technician is recommended. Compound microscopes should typically be serviced after about 200 hours of use. For most schools, this would certainly be about every three years, possibly more frequent if the microscopic lense is supplied multiple times each day. Over there is a an excellent article here around how to avoid microscopic lense repairs.

You are watching: Why is it important to keep a microscope covered when you’re not using it?

Microscope Handling and also Storage

Most microscope problems occur as a result of wrong handling. Once carrying the microscope, constantly hold that by the base and also the steel support arm. Perform not choose it up by grabbing the stage, as this can reason mis-alignment for the mechanical stage. If you will certainly be transporting the microscope frequently from one place to an additional you might think about purchasing a microscopic lense carrying case.

When the microscopic lense is no in use keep it spanned with the dust cover. This alone will extend the life of her microscope. Also if the microscopic lense is stored in ~ a cabinet, you should still sheathe it through the dust cover. Carry out not save a microscope without any kind of eyepieces, even if the is covered. This can allow dust to collect within the eye tubes, which can be challenging to clean. If the microscope eyepieces should be removed, merely cover the tubes v caps or a plastic bag v a rubber band around the eye tube.

If you space using immersion oil the high strength objective lens (usually 100x) and also the lens that the condenser have to be thoroughly cleaned prior to storing. After using the microscope, turn off the illuminator and wait because that it to cool for numerous minutes before putting that away. By permitting the bulb to cool friend will expand its life. Also, make sure you perform not store your microscopic lense in one area that has corrosive chemical fumes the can destroy lenses or metal parts.

Cleaning microscope Eyepiece Lenses

Microscope lenses can easily be scratched and also should be cure with great care. Never use sharp tools or anything abrasive come clean the microscope lens. To clean the microscopic lense eyepiece or the microscopic lense objective lens, moisten lens paper with lens clean solution and clean the lens v a circular motion. You can dry the lens with a clean, dry piece of lens document and as soon as you room finished usage an aspirator come remove any kind of lingering dirt or particles.

To identify if your microscopic lense eyepieces need cleaning, loosen the small set screw because that the eyepiece (if over there is one) and also rotate the eyepiece in a circular activity while looking with the microscope. If there is a dust bit that rotates as you revolve the eyepiece, remove the eyepiece native the microscope and clean both political parties of the lens v lens paper. If you must use any type of liquid for cleaning, distilled water is recommended. It is no recommended that you take it the eyepiece apart, together there are usually multiple lenses in the eyepiece and also they can be an overwhelming to put ago together in the correct order.

Cleaning Objectives

In bespeak to identify which of your objective lenses need cleaning, take it a clean blank glass slide and also put that under your microscope. As soon as the microscope is focused you should have the ability to move the slide and determine if the visible dust is relocating with the slide or remaining in the same location (which means the dust is top top the objective lens).

When using immersion oil because that microscopy, the oil should always be cleaned from microscopic lense objective lenses automatically after use. This deserve to be done through a kimwipe of piece of lens paper, no cleaning solutions are needed. Periodically dust may build up on the lightly oiled surface ar so if you great to fully remove the oil climate you must use an oil dissolve solvent. For the Cargille form A or B immersion oil that us sell, you can use Naptha, Xylene, or turpentine (use very small amounts on the kimwipe). Perform not usage water, alcohol or acetone together the oil is insoluble to these solvents. To remove various other oily substances, we recommend making use of the detergent dubbed Wisk and prepare a systems of 1 component Wisk to 100 parts water.

If immersion oil was not cleaned off an objective after use and has hardened top top the objective, moisten a piece of lens document with a small amount of distilled water and also hold it versus the lens because that a couple of seconds to dissolve the oil. If that does no work, try alcohol. Isopropyl alcohol is just one of the ideal solvents but it must be at least 90%+ pure (do not use rubbing alcohol, 30% water). Everclear i beg your pardon is grain alcohol (you should be 21!) can also be used yet it doesn"t do also in dissolving crud. If you have actually something favor Balsam stuck on the lens, you should resort come a stronger solvent choose Acetone or Xylene. Acetone have to never be placed on plastic parts, as it will certainly dissolve many paints and also plastic. After making use of solvents be certain to clean the objective again with standard distilled water come ensure that you have actually removed every the solvents native the microscopic lense objective.

Mechanical Maintenance

Each microscopic lense should come through a user"s manual. Constantly consult this user"s manual before making any kind of adjustments to your microscope. Never ever over-tighten or use force when performing any type of maintenance on her microscope. This can damage metal components in the microscope.

Microscope chart Nosepiece Adjustment

The microscopic lense nosepiece deserve to sometimes come to be too loosened or tight. Normally there is one adjustment mechanism on the nosepiece. A basic loosening or tightening that the slot-headed screw in the middle of the nosepiece will usually resolve the problem. Check your user"s hand-operated for complete instructions.

*
Adjusting the focus Knob

You can change tension that the fine and coarse concentrating knobs. Some microscopes are changed by turning the knobs on every side of the microscope in opposite directions. Other microscopes will certainly have flexible collars top top the shaft and also require the use of unique wrenches to make adjustments (these normally come with the microscopic lense when purchased). Moving the collars out usually provides an ext tension.

See more: What Are The Factor Pairs Of 80 In Pairs, Factors Of 80

*

Lubricating Surfaces

On an annual basis moving parts top top the microscope should be cleaned and lubricated. Clean grease and dirt from sliding surfaces utilizing a clean cloth. Apply a an extremely thin layer of lithium-based grease come the sliding surfaces. Carry out not grease the teeth of the rack and pinion gears. ~ lubricating, if the coarse adjustment moves too freely, change the tension knob as defined above.

Replacing Bulbs

Microscope bulb replacement instructions can be found in the microscopic lense instruction manual. Be certain to usage the exactly replacement bulb. Always permit the pear to cool prior to replacing it. Avoid poignant the glass of the bulb with your ceiling hands, as fingerprints and particles that dust left ~ above the bulb have the right to burn into the bulb and reduce the life the the bulb and the quality of the light produced by the bulb. LED light bulbs have tendency to critical the longest, typically 100,000 hours. In comparison, tungsten bulbs typically will no last longer than 100 hours.